Find the right product
Method 1:Enter product's part number:
Choose desired product category:
EMC1013
Electrical specifications and compliance Matrix
30dB Line Amplifier
Parameter |
Specification |
Condition/Remark |
|
|||
|
Min |
Typ. |
Max. |
Unit |
|
|
Input/output Frequency |
950 |
|
2150 |
MHz |
|
|
Gain 20dB model Gain 30dB model |
19.5 29 |
20 31 |
22 32 |
dB dB |
Over operating freq range and over operating temp range (Positive slope is acceptable) |
|
Return Loss(In/Out) |
11 |
|
|
dB |
|
|
Noise Figure |
|
|
6 |
dB |
|
|
3rd order IMD(20dB) |
36 |
|
|
dB |
@>105dBμV Output level Definition per ENBS50083 |
|
3rd Order IMD(30dB) |
35 |
|
|
dBc |
@>115dBμV Output level Definition per ENBS50083 |
|
RFI:ingress/Egress@ output |
70 80 |
|
|
dB dB |
20dB 30dB |
|
Gain Flatness |
|
|
1 2.5 |
dB dB |
Ptp@any 36MHz Ptp@operating freq range |
|
RF Connectors |
|
75 |
|
Ω |
“F” Female. Comply with IEC61169-24 Standard.See below |
|
Operating Voltage |
11 |
|
19 |
V |
|
|
Opterating Current |
|
|
100 |
mA |
|
|
DC Power Passing |
|
|
500 |
mA |
Power pass from OUT→IN Power pass from DC IN→IN Power block OUT→DC IN Power block DC IN→OUT Power block IN→OUT Power block IN→DC IN LED Indication for POWER ON(applied to OUT or DC IN only )
|
|
Operating Temperature |
-10 |
25 |
+60 |
℃ |
All specifications above shoul be met within the indicated temperature range. |
|
Humidity |
|
|
100 |
% |
|
|
Robustness |
|
|
|
|
Comply with IEC68-2-32Proc1 Free fall up to 1000mm |
|